1U10 RBOD User’s Manual
Copyright© 2010 Advanced Industrial Computer, Inc. Page 16 of 72
All Rights Reserved. Rev.1.05
2.5.1. Removing a PSU Module
1) Remove any power cables connected to the PSU module.
2) Allow a minute for fan to spin down.
3) Loosen PSU module retaining thumbscrew.
4) Grab the handle and gently pull the PSU module out of the slot until it clears the chassis.
5) Place in anti-static bag or container prior to storage or shipment.
2.5.2. Installing a PSU Module
1) Remove any packing material and cover.
2) Hold the PSU module and align it with the slot opening in the rear of the enclosure. Slide
in until PSU is fully engaged.
3) Secure PSU module retaining thumbscrew.
4) Connect AC power cable to Module. If system is operational during installation, the PSU
module will self test and fan will begin operation. LEDs will reflect status.
2.6. External Connections
2.6.1. Single Host to Enclosure Connection
A single Server may be easily connected to a wide SAS channel on the Expander using the
SAS/FC cable (available separately). The figure below illustrates a typical connection.
Figure 2.5: 1U 10-Bay RBOD connected to host
2.6.2. Multiple Host to Enclosure Connections
The system may be connected to multiple servers via direct attachment to the Expander Channels
or by using a SAS switch. The expanders may be used to optimize operation in multi-host
configurations.